0102030405
SMT Automatic Standard PCB Filter
![Standard PCB Filter01w48](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/66262d18e15e589192.jpg)
01
7 Jan 2019
● Reject, inspect and pass through modes provided
● Modular design
● Stable enhanced by 'robust design'
● Inducing multi-zone position accuracy
● Ergonomic design,make arms rest
● Different lengths available upon request
● Muti-zone concept available upon request
● variable speed control
● SMEMA interface
Operation Diagram
![image001wup](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/66262d6342bfd90059.png)
Technical Parameters
Technical Parameters | |
Description | This unit allows good and bad board separation in AOI ,during testing ,the good board can continue to run without interruption |
PCB size | 50*50-330*250-530*460 |
Belt type | Antistatic oblate belt |
Conveyor speed | 0.5-20M/min or customer specefied |
Power supply | AC1P110V/220V |
Power | Max 300VA |
Storage plate number | 8 pcs(or specify) |
Storage plate distance | 4-6bar,10ltr/min max |
Transport height | 900±20mm(Or customized) |
Transport direction | From left to right or right to left |
Application
![partner013wz](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635b7c77f545785.jpg)
![partner02ahm](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635bf2434530446.jpg)
![partner036mw](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635c5779bb63609.jpg)
![partner0487b](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635cce4a3f12204.jpg)
![partner0586w](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635d3a673c26969.jpg)
![partner06dqi](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635da7607691097.jpg)
![partner074dz](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635e50cb1e41487.jpg)
![partner08va4](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635ec222ed58953.jpg)
![partner092t7](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635f32f91d27654.jpg)
![partner10h7r](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662635f99dbcd58167.jpg)
![partner11jlp](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662636021c95765708.jpg)
![partner12iyt](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/66263614e0fa433502.jpg)
![partner13umz](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/6626361cccec442388.jpg)
![partner14877](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662636257f4fe99345.jpg)
![partner15m91](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/6626362ddf1c224709.jpg)
![partner16qsi](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/66263640a911184377.jpg)
![partner17pgj](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/6626364831b6931636.jpg)
![partner18h15](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/6626365300cce57378.jpg)
![partner19i5n](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/6626365b000b715401.jpg)
![partner20xmy](https://ecdn6.globalso.com/upload/p/1177/image_other/2024-04/662636628ed0081864.jpg)
FAQ
Q: Why does it report that the board is entering the protection sensor, or that the lifting sensor is reporting the protection sensor?
A: Check the parameter settings and reduce the loading time. Or check whether the sensors on the entrance and exit are abnormal.
Q: What should we do if the automatic alarm indicates that the cylinder is not at the origin?
A: Check whether the air pressure is turned on, and secondly, observe whether the sensor on the cylinder responds. Is it abnormal? Or check whether the air pressure is turned on, and secondly, observe whether the sensor on the cylinder responds. Is it abnormal?
Q: What is the size of pcb?
A: 50*80-530*460 (Customized).