X-ray Offline XC-3100 Counting System

XC-3100 is mainly used for rapid counting of reel-type materials in the SMT industry. It can count all types of materials such as 7-15-inch Tape Reel/JEDEC Tray/IC moisture-sensitive packages. The material types include all resistance-capacitance materials and IC materials. Use X-ray imaging technology to detect production materials and obtain image information for rapid counting, and connect equipment data information with the customer's MES system.

    Functional Interpretation

    Offline-XC-3100-Counting-System6_02zci
    01

    Inductive printing material label function

    2018-07-16
    With nectar and honey pouch Although I didn't bring a honey jar But there is a honey pouch in the belly of the bee Is specially used to hold nectar
    view detail
    The inductive printing material label function effectively prevents mislabeling, random labeling, and missing barcode labeling, and improves the accuracy of information entry.
    Offline-XC-3100-Counting-System71vk7
    01

    Inductive printing material label function

    2018-07-16
    With nectar and honey pouch Although I didn't bring a honey jar But there is a honey pouch in the belly of the bee Is specially used to hold nectar
    view detail
    Save time and improve efficiency, automatically read barcodes. 
    Offline-XC-3100-Counting-System4ik6
    01

    Multi-reel and single-reel functions can be ordered.

    2018-07-16
    With nectar and honey pouch Although I didn't bring a honey jar But there is a honey pouch in the belly of the bee Is specially used to hold nectar
    view detail
    Offline-XC-3100-Counting-System53k2
    01

    Choose single/multiple inventory material mode according to needs.

    2018-07-16
    With nectar and honey pouch Although I didn't bring a honey jar But there is a honey pouch in the belly of the bee Is specially used to hold nectar
    view detail

    Technical Parameters

    Technical

    Tube

    Model XC-3100
    Tube type Closed shut pipe
    Spatial resolution 30μm
    Tube voltage 50KV (actual 80KV,limit 50KV)
    Tube current 1000μA

    Tablet

    Image acquisition method Flat-panel digital imaging
    Imaging accuracy 139μm
    Image size 430*430mm
    Resolution 3072*3072px
    Pixel accuracy ≤2μm

    Camera

    Imaging speed 5 EDS/s
    Code reading pixels 20 million inches

    Tablet

    Misjudgment rate ≤0.01% (0201 for example)
    Accuracy 99.99% (0201 for example)
    Minimum part size detectable Imperial 1005
    Order record keeping Save by day,no capacity limit,TXT.CSV.XLS
    Operating system WINDOWS 10
    Power supply/power AC110-220V 50-60HZ 1200W
    Radiation safety test <1uSV/H
    Repeatability testing ≥2.0sigma
    Cycle time ≤10s/time

    Structure

    Counting speed 6-10 S/4 reels (CHIP 0201)
    Maximum disc diameter detectable 415mm (4-15INCH)
    Maximum height of checkable material tray 1-80mm
    Maximum weight of detectable reels ≤10kg
    Machine size 730*1460*1960mm(L*W*H)
    Machine size (Including printer) 950*1460*1960mm(L*W*H)
    Machine weight 450kg

    Honorary Customer

    partner01dx4
    partner02pyk
    partner0352q
    partner04wln
    partner05j6o
    partner08lhv
    partner09kla
    partner06grx
    partner07t1u
    010203040506070809

    FAQ

    1.What to do if the software cannot be started?
    Turn on the emergency stop and restart the software.

    2.When ordering ingredients, the ordering position is not accurate.
    A. First check whether the image is clear.
    B.Click the inaccurate material three times in a row, take the original image from the D drive-OK file, compress it and send it to the supplier for model optimization. After the model is optimized, the supplier will contact you to update the latest model.

    3.Why does the camera fail to open?
    A. Whether the emergency stop is turned on.
    B. Is it possible to communicate if the MVS software is opened?
    C. Whether the camera network cable communicates normally.

    4.Why does the tablet fail to open?
    A. Whether the emergency stop is turned on.
    B. Whether the tablet network port has been changed and reset the IP 192.168.8.188 (network configuration)
    C. The last time the program did not exit and complete, just restart it.